Release notes IMPACT for AutoCAD & BricsCAD 16.0.011

Last modified by Dennis Knudsen on 2021/02/19 09:52

New

New: Wires are now shown for 3D solid for Prestressed slabs on the shop drawing. (Case 97464)
New: Two new reinforcement default settings "MTO_HIDE_GROUP_BARS" value 1 hides straight bars from reinforcement groups in the table of reinforcement. "MTO_HIDE_GROUP_STIRRUPS" value 1 hides stirrups from reinforcement groups in the table of reinforcement. Note these settings needs to be combined with "GROUP_MTO_PARTS" to have any effect. (Case 99467)
New: Symbol added for the back side of the wall. (Case 99538)
New: straight bars now react the same way as other stirrups regarding edit depth command when seen from left and right. (Case 99288)
New: Split Doublewall with id should keep id, element mark and shop drawing for one of the elements. (Case 99706)
New: Show endcap label text for Hollowcore on floor plan. (Case 97579)
New: Setting to show lift point symbol as Mountpart in the Unitechnik file. the new variable in Standard Admin is called "UNITECHNIKLIFTSYMBOLASMOUNTPART". (Case 100413)
New: Save as on floor plans and elevations on a filesync projects is now correctly handled. (Case 99757)
New: Reinforcement template for slabs double mesh and and double rebar should place the bars either related to top or bottom. (Case 90322)
New: Possibility to set cover for the girders to the top of lowest shell of the Doublewall with the Standard Admin variable "COVERGIRDERSATTOPOFDOUBLEWALL". (Case 99189)
New: Possibility to continue connecting walls with the same joint without restarting the command. (Case 99798)
New: Open drawing from floor plan/elevation on a file sync project should have the possibilities for lock and synchronize files. (Case 99705)
New: Mulitple placing options added to the simple column top. (Case 98841)
New: It is now possible to name stirrups from reinforcement groups in sections. (Case 99539)
New: Improvements to panel ties so it also supports wall ties. (Case 51792)
New: Improved modeling of sloping slabs including Form Slabs. (Case 73651)
New: Generate shop drawing should lock and sync the new drawing files. (Case 47661)
New: Export the Unitechnik files to the drawing folder according to the project properties. (Case 98705)
New: Draw mesh do now keep the "Session" and only do the MTO after finishing the command. (Case 97344)
New: Cobel dimension moved to the "Right elevation view" on columns when it's placed in Front or Back. (Case 98842)
New: Closing saved IMPACT drawings in AutoCAD should ask about unlocking file. (Case 47662)
New: CIM templates for hollowcore elements in IMPACT is now possible. (Case 98666)
New: Bracing anchor height relative to wall bottom elevation in schedule. (Case 99823)
New: Apply cim template now allows individual selection of previous cim templates to be removed. (Case 99399)
New: Add the possibilty to have more than one insulation material in the endcap. (Case 73338)
New: Add filling for the cover of the lifts in sandwich and insulated wall automatically. (Case 44260)
New: "Line + Box" option is now available for drawing mesh on the shop drawing. (Case 94381)

Fix

Fix: Wrong values in area and weight when adding recess to wall. (Case 98912)
Fix: Where endcap label for slab and prestress slab were not working as intended. (Case 100055)
Fix: Where CIM in corbels are not dimensioned correctly. (Case 97171)
Fix: When a MEP-Key/Cast-in Material is set to the left/right side then you only get a vertical annotation line. (Case 99250)
Fix: Variable DWGDIMHCSLIFT was not working as intended. (Case 99729)
Fix: The reinforcement connected to CIM on slabs can't handle distribution line. (Case 100296)
Fix: Switching between half and normal scale reinforcement on the shop drawing and updating the elevation did not change the reinforcement template on the elevation. (Case 100605)
Fix: Strands for prestressed slabs disappeared after making changes in the shopdrawing. (Case 99602)
Fix: Special case where the endcap was shown incorrectly in the section. (Case 99852)
Fix: Special case where the bar mesh didn't get divided correctly. (Case 100188)
Fix: Special case where the 3D picture of the reinforcement group was incorrect. (Case 100450)
Fix: Special case where barmarks for straight bars get generated automatically on shopdrawing although MTO is set to off. (Case 89349)
Fix: Shows correct edge reinforcement now. (Case 94536)
Fix: Section outside of the element on shop drawing implemented for prestressed slabs. (Case 97252)
Fix: Resolved the issue where the geometry of the hidden lines in the horizontal section was inverted. (Case 99728)
Fix: Resolved a case where the geometry of the vertical section was not represented correctly. (Case 99727)
Fix: Resolved a case where the geometry of the lines in Shop drawing was flipped. (Case 96993)
Fix: Reinforcement was not visible on the section view in columns. (Case 98667)
Fix: Reinforcement template/proposal produces bugs in Half scale. (Case 100641)
Fix: Reinforcement connected to CIM for slabs is redrawn although it has been edit in the correct way. (Case 100299)
Fix: Reducing length from elevation deletes element If top is inclined. (Case 99923)
Fix: Recess was changing it's basepoint from the floor to the element. (Case 93817)
Fix: Recess moved up after "Regroup wall" which made the recess option "Distance from base" to show wrong values. (Case 84586)
Fix: Placement and measurement of the MEP-Key dimension in sections. (Case 100044)
Fix: MEP Key placed at back and mirror bug. (Case 99246)
Fix: Material take off on Hollowcore shop drawing removes connection between lift and core filling. (Case 99243)
Fix: LCIM - "distance from base" is incorrect when inserted in a column. (Case 99388)
Fix: Horizontal section for elevation does not show cast in material. (Case 99450)
Fix: Generate schedule based on ElementID sorts the values wrong. (Case 99925)
Fix: Generate schedule ask for save multiple times although nothing has change. (Case 98620)
Fix: Floating CIMs in IFC-Solid 3d DWG. (Case 99973)
Fix: First time generating shop drawing for slabs section reinforcement text will appear although I have turned it off in project properties. (Case 97568)
Fix: Errors while editing converted reinforcement groups. (Case 98827)
Fix: Error in length and height while editing due to 0.0 precision for length in unit settings. (Case 100855)
Fix: Entered text on treatment of CIM will not be included when CIM is included in an electric key, if it is not a VP pipe. (Case 99471)
Fix: Endcaps kept "varies" when editing properties on multiple slabs and then editing just one slab. (Case 99664)
Fix: Element mark position adjusted to fit with the mould sign on the floor plan. (Case 99313)
Fix: Electrical duct not appearing in the reinforcement view after MTO. (Case 100564)
Fix: Edit multiple DoubleWalls and change lifts in other edge doesn't work. (Case 99978)
Fix: Edit mesh in Slabs doesn't work. (Case 99558)
Fix: Edge Recess dimensions in beams with end-sections shown correctly. (Case 97247)
Fix: Doubleclicking on attribute block redirects to the selected part of the block. (Case 97224)
Fix: Double wall accessories no longer on layer "0" when the double wall is deleted and then generated back to the drawing. (Case 99387)
Fix: Dimension text clashes with others and rebar geometry in Reinforcement group section. (Case 99154)
Fix: Check Producibility no longer checks the reinforcement groups. (Case 99885)
Fix: Bar mesh - Inside and outside text is incorrect when the side is "Back". (Case 99534)
Fix: "Lift other edge" changes sides when editing wall definition. (Case 99948)
Change: The Variable FRONTWALLPANELVOLUMEFACTOR now only applies when there is insulation in the element. (Case 90261)