Release notes IMPACT for AutoCAD & BricsCAD 16.0.020

Last modified by Dennis Knudsen on 2021/12/21 11:16

New

New: Possibility to remove previously added lifts and fillings in hollow core shop drawings. (Case 110706)
New: Possibility to define cutting angle for draw wall outline. (Case 109471)
New: Possibility to customize section labels through variable "DWGTEXTSECTIONTITLE". (Case 108774)
New: Possibility to customize section labels through variable "DWGTEXTSECTIONTITLE". (Case 105397)
New: Offset distance barmesh for rectangular hole should also consider openings with keep mesh. (Case 109700)
New: New variables "DWGSHOWSINGLESECTIONNAMEBEAM" and "DWGSHOWSINGLESECTIONNAMECOLUMN" for displaying the section name even when there's only one section in the beam or column. (Case 111467)
New: Mesh description now is available on sections (Wall and slab) as parameter: "MESH_TEXT_SECTION". (Case 111372)
New: I-Shape Beams with possibility of different width for the bottom flange. (Case 108755)
New: Drawing Status Review should work as Preliminary in CAD. (Case 111187)
New: Check if the drawing is locked (if the project is in a file sync project) if not don't allow to save the dwg file. (Case 111718)
New: Change default option for remove the element mark to "no" when removing the last element of that mark. (Case 74954)
New: Add texts in the element mark block MarkTextFormSlabPlan for the reinforcement in primary "RC_PRIMARY" and secondary direction "RC_SECONDARY". (Case 110335)
New: Add a warning for lift point for FormSlabs to warn if they are placed in a hole. (Case 110671)

Fix

Fix: Wrong elevation after using replace. (Case 112069)
Fix: where to edit length for form slabs were not working as intended when lengthening the element affected the insert point. (Case 110478)
Fix: where geometry moved to the original insert point when elements got edited in the width. (Case 111743)
Fix: were MEP key in an element with other endcap was not working as intended. (Case 110500)
Fix: We are missing the dimension of radius for openings with radius in top but with rectangular freeze. (Case 111118)
Fix: Use same reinforcement type in the Unitechnik export if the DoubleWall is a turning wall or a normal wall. (Case 109586)
Fix: Split wall vertical on elevation now applies the gap on all selected walls. (Case 111889)
Fix: Split wall on elevation with a joint with overlapping endcaps doesn't split the walls correct. (Case 111041)
Fix: Special Case with overlapping overall dimension. (Case 109305)
Fix: Special case with Hollowcore vertical dimension line placement. (Case 105330)
Fix: Special case where the direction arrow for FormSlab was removed when the element edge was changed. (Case 112196)
Fix: Special case where the bar mesh didn't get cut. (Case 110913)
Fix: special case where switching sides for the bracing was not working as intended. (Case 109276)
Fix: special case where recess for MEP keys were not working as intended. (Case 109630)
Fix: Special case where AutoCAD freezes at Draw Barmesh at specific area. (Case 110050)
Fix: Special case where a tapered recesses were missing dimensions on shop drawing. (Case 111827)
Fix: Sorting issue for "items" in MEP keys. (Case 109573)
Fix: Shape Code J shown as 3D in the solid. (Case 112077)
Fix: Save as for Doublewall and Formslab is not working correct. (Case 108692)
Fix: Resolved special case where the CIM could not be added to a user-defined column. (Case 110057)
Fix: Resolved an issue where the double mesh was represented as a single in the Shop drawing. (Case 109935)
Fix: Resolved an issue where AutoCAD crashed after adding other endcap. (Case 109680)
Fix: Remove CIM in endcaps and openings from the Unitechnik export. (Case 110560)
Fix: Reinforcement changing bar spacing when replaced in project. (Case 110375)
Fix: Reinforcement "Graphic" now also gets applied to the section. (Case 109725)
Fix: Problem with inserting slab when definition width was set to 0 and the SA variable "DWGDIMFLOORPLANCUTSLAB" was set to 1. (Case 112046)
Fix: Polygon recess is no longer removed from the element when clicking on MTO. (Case 109920)
Fix: Not syncing the file on "Open Drawing" if the status is "New file on cloud". (Case 110108)
Fix: MEP key dimension for none point bug shop drawing. (Case 109225)
Fix: Linear CIM representation issue on 'back' side. (Case 111960)
Fix: IFC solid walls at wrong location. (Case 111096)
Fix: Having a shop drawing open and doing a "save as" on an elevation caused a fatal error. (Case 111748)
Fix: Form slabs - hole filling material no longer return to none after update plan. (Case 109781)
Fix: Fixed an issue where the recess could not be added to the element. (Case 110480)
Fix: Fixed an issue where the opening had a negative thickness value. (Case 110796)
Fix: Dynamic cast in material was placed wrongly when selecting top and defining a distance. (Case 111510)
Fix: Disappearing geometry in plan view after MTO. (Case 110360)
Fix: Dimension numbering after 'Z' adds small letters. (Case 109797)
Fix: Dimension line order - MTO / Draw element. (Case 102084)
Fix: Dim-Numbers of DCIM change automatically to random. (Case 112267)
Fix: Difference in CIM rotation in plan and shop drawing for column top. (Case 111094)
Fix: Created Date and Created By is removed from Reinforcement Barmark when they are resaved. (Case 110130)
Fix: Connect sandwich walls on elevation is not including joints which include solid walls. (Case 111047)
Fix: Can not check some boxes in print schedule. (Case 110083)
Fix: Bracing default side on Double Walls is now set to "Back" instead of "Right". (Case 102105)
Fix: AutoCAD crashes when a "Layout" & "Other" drawing were opened at the same time and one of them was saved and sync was active. (Case 112095)
Fix: AutoCAD crash when a shop drawing is generated without sync. (Case 111093)