Release notes IMPACT for AutoCAD & BricsCAD 16.0.016

Last modified by Dennis Knudsen on 2021/09/10 10:36

New

New: Switch panel on a doublewall should ask a question about the bracing side. (Case 106678)
New: Support for minimum crane radius. (Case 106203)
New: Support for BricsCAD V21.2.03. (Case 93369)
New: Strandpattern description now is available as  parametrer named: "DWGTEXTSTRANDPATTERN". (Case 106388)
New: Recognize AutoCAD layout as an IMPACT Layout. (Case 105350)
New: Possibility to customize the text showing the scale of sections by using a new variable named "DWGTEXTSECTIONSCALE". (Case 106322)
New: Now possible to write in endcap name in opening endcaps. (Case 105434)
New: Now it is possible to move the dimension line for cut slabs after the slab has been saved. (Case 108028)
New: Improved "Draw recess from element" command. (Case 82608)
New: Corbel that is sticking out of an element can now be shown on the section in the shop drawing. (Case 100461)
New: Command "Draw Recess from Element" should be able to use a solid when subtracting from other elements. (Case 105669)
New: Command "Draw Recess from Element" should be able to use a linked element drawn as solid when subtracting from other elements. (Case 105668)
New: CIM groups added to "Schedule". (Case 100719)

Fix

Fix: where straight bars outside of the geometry where missing in the section. (Case 100325)
Fix: where straight bars in prestressed beam got placed in wrong place based on the reinforcement definition. (Case 100331)
Fix: where panel ties were not following elevated elements. (Case 107952)
Fix: Wall Error in calculation of centroid for odd shapes in elevation. (Case 102394)
Fix: The reinforcement template no longer draws out bars if the length is zero. (Case 108642)
Fix: Text inside the position number was offset. (Case 105725)
Fix: Text for the reinforcement connected to a CIM is moved to its origin after a move & MTO for cast type mirror x-axis. (Case 105528)
Fix: Special case where the lift name in element properties was incorrect. (Case 102190)
Fix: Special case where the beam geometry was not drawn in AutoCAD. (Case 107989)
Fix: Special case where recess in endcaps disappears when height of wall is reduced. (Case 105019)
Fix: Special case where connection failure lead to disappearance of MEP key. (Case 108241)
Fix: Resolved the issue where the opening cross lines were not displayed in the Elevation. (Case 106430)
Fix: Resolved the issue where the CIM could not be added to a user defined column. (Case 108045 )
Fix: on lower walls, CG measurement was overlapping other information. (Case 107790)
Fix: Normal bars changed to staggered bars no longer switch back to normal when the drawing is saved and opened again. (Case 105332)
Fix: LCIMs in RC view only used visible layer. (Case 106400)
Fix: LCIM in insulation ejects the insulation hatch in shop drawing. (Case 108331)
Fix: Geometry on reinforcement view did not change after MEP key is changed until MTO is done twice. (Case 103895)
Fix: Export to Unitechnik concrete quality missing for sandwich, solid wall and insulated wall. (Case 105565)
Fix: Edit MEP-Key on right-click on an MEP-Key. (Case 105524)
Fix: Dimension line for end holes on a "User Defined" beam profile. (Case 106303)
Fix: Depth on LCIM Starts on "-". (Case 106393)
Fix: Bold drawings after "Generate shop drawings". (Case 102033)
Fix: Adding recess from left side in BricsCAD had wrong placement. (Case 106646)
Fix: added VOLUME_CONCRETE_L and VOLUME_CONCRETE_M3 as attributes for sandwich walls. (Case 108360)
Fix: "Remove Leading Letters" in Batch Generate. (Case 105215)

 