New

New: Extents of holes in the hole specification for polygon holes for FormSlab. (Case 117113)

New: Add a warning to the producibility control if there is no reinforcement in the drawing. (Case 120129)

Fix

Fix: Draw Beam with changed justification point gets wrong Z value first time. (Case 121004)

Fix: Where Edit Recess/Filling was missing in right-click menu for double-polygon recess/filling. (Case 121596)

Fix: New variable added "MINWIDTHFORMSLAB", (default 10 mm) which serves as a minimum width when drawing form slabs. (Case 121357)

Fix: Special case where the reinforcement rotation was incorrect in the Unitechnik export. (Case 121520)

Fix: Drawing Status was not exported when doing an IFC export. (Case 121283)

Fix: Lift information empty on new lift. (Case 121203)

Fix: Scrolling after deleting a lift in the element definition. (Case 121125)

Fix: Special case where "Generate Plan" failed to draw a prestressed slab. (Case 121030)

Fix: Double wall - Edit Length - Caused AutoCAD to freeze due to the bracings' new location. (Case 120681)

Fix: Special case where LCIM in an opening was causing reinforcement contour lines to disappear. (Case 120753)

Fix: "Update all" is only applied for one element when using "Copy endcaps from". (Case 120935)

Fix: "Disconnect reinforcement" was unchecked when a CIM was added to the wall on the elevation drawing. (Case 120939)

Fix: Pressing Esc instead of using "Exit" while modifying properties of FormSlab. (Case 120418)

Fix: Canceling saving beam didn't work properly. (Case 120515)

Fix: Special case where the mass of bended mesh wasn't correct. (Case 120569)

Fix: Splitting walls on elevation with a recess that crosses the element border removes the recess from the elements instead of splitting. (Case 120477)

Fix: Special case where a Double-Polygon Recess is added outside of the element. (Case 120424)

Fix: Circular recess drawn into two elements on elevation doesn't split up between the elements. (Case 71337)

Fix: User-defined mass is ignored when canceling MTO. (Case 120281)

Fix: Adding openings that are parallel with the top does not get added to the sandwich wall, caused by a difference in the 5th decimal. (Case 120294)

Fix: where endcap dimension was placed inside the geometry. (Case 119647)

Fix: Special case where the MEP-key ducts caused an invalid element solid when they were subtracted from the element's solid. (Case 119824)