New: Added reinforcement area mesh drawing view for shop drawings. Now all area meshes will be lined up similarly to reinforcement groups. (Case 122681)

New: The reinforcement setting "GROUP_FROZEN_COLOR_RGB" also accepts a single color index (1-255), this makes it possible to plot frozen reinforcement groups in monochrome. (Case 122690)

New: Make a new setting to allow the cast-in material GEO files to be mirrored for View6 for all element types in the Unitechnik export. (Case 122648)

Fix

Fix: Recess is duplicated when added to the element. (Case 123279)

Fix: The diagonal lines in recesses were not always shown on the elevation drawing. (Case 123406)

Fix: Special case where the thickenings for lift in left/right side of the wall didn't have the correct dimensions. (Case 123415)

Fix: Special case where the slab geometry was drawn incorrectly. (Case 123426)

Fix: Set 'Ready for Production' on an elevation drawing didn't work. (Case 123481)

Fix: Special case where changing the depth of a reinforcement group changed the countersinking of a filling incorrectly. (Case 123244)

Fix: Where other endcaps on the left side were dimensioned in a different way than on the right side. (Case 122880)

Fix: Special case where the edge reinforcement wasn't joined properly. (Case 123012)

Fix: Fixed the issue where IMPACT was asking the user to replace the dynamic CIM definition when renaming it. (Case 123059)

Fix: Fixed the issue where the reinforcement schedule was empty after editing the element. (Case 123003)

Fix: Updating the plan resulted in a crash. (Case 122854)

Fix: Fixed an issue where the questions related to CIM views were not displayed. (Case 122885)

Fix: Fixed the issue where the drawing could not be saved. (Case 122144)

Fix: Recess at an edge was not displayed correctly if LCIM was passing thru the recess. (Case 121657)

Fix: If a wall had an angle adding LCIM to that wall, angle rotation was not consistent. (Case 79350)

Fix: Adding breakpoints from element properties removes the "Thickness filter" for Endcap selection. (Case 122697)

Fix: Draw wall on plan without definition. (Case 122767)

Fix: Error when erasing in BricsCAD. (Case 122261)

Fix: Fixed the issue where the recess shape changed when running the commands add and remove all. (Case 122545)

Fix: Special case where dimension reference disappeared from CIM table when saving the drawing. (Case 122748)

Fix: Unable to add vertex on form slabs in properties. (Case 121945)

Fix: Incorrect COG on drawings for double walls with nonsymmetrical panels. (Case 122381)

Fix: AS1 shows an incorrect number on the shop drawing after using "Update Drawing". (Case 122262)

Fix:  Hollowcore wall - Changing length moves the element marks. (Case 122025)

Fix: Not possible to add panel thickening on elevation. (Case 122221)

Fix: Generate plan no longer resets "UCSFOLLOW" to zero. (Case 122327)

Fix: Special case where edit reinforcement group did not work as intended. (Case 121863)

Fix: Special case where Unsupported operation in BricsCAD happened. (Case 122258)

Fix: Special case where floor 1 wasn't selectable in "generate plan". (Case 121998)

Fix: Mirror reinforcement group caused the reinforcement name to jump around. (Case 122143)

Fix: New variable "UNITECHNIKTRIMMOUNTPARTGEODATA" added so Geo files aren't getting trimmed when exported to Unitechnik. (Case 12637)

Fix: New variables so Geo files aren't getting trimmed when exported to Unitechnik. (Case 121848)

Fix: Dimensions showing wrong in elevations for circular openings. (Case 121640)

Fix: Dynamic CIM is rotated when adding it to the formslab. (Case 121712)

Fix: The element mark is moved back to the default placement when updating the element on the elevation drawing. (Case 121717)