1 +(% class="row" %)
2 +(((
3 +(% class="col-xs-12 col-sm-8" %)
4 +(((
5 +(% class="wikigeneratedid" id="HHeader" %)
6 +IMPACT parameters for CIM families will help you connect the Revit CIM with the IMPACT database. IMPACT parameters will be displayed on the shop drawings, Standard Admin and will help you identify Revit CIM with IMPACT CIM from the database.
7 +
8 +
9 += Necessary parameters =
10 +
11 +There are some parameters that the user has to add to their family in order to make the CIM work with the IMPACT BIM system. There are four IMPACT parameters, that the user must add to their families in order to fully utilize the possibilities of the IMPACT drawing system: IMPACT CIM Type, IMPACT CIM Mark, IMPACT Schedule, UNique Mark Controller.
12 +
13 +
14 +== IMPACT CIM Type ==
15 +)))
16 +
17 +(% class="col-xs-12 col-sm-4" %)
18 +(((
19 +(% class="box" %)
20 +(((
21 +{{toc/}}
22 +)))
23 +)))
24 +)))
25 +
26 +There are different types of CIM defined in the IMPACT database. IMPACT CIM Type parameter is used to identify different types of Cast in Materials, available in the IMPACT database.
27 +
28 +The user is allowed to choose a type from the list with CIM types below. If the type of the CIM can not be defined, the user is advised to choose value ´´M´´ for Manual type.
29 +
30 +
31 +[[image:IMPACT CIM type.png]]
32 +
33 +//Figure 1 - IMPACT CIM Type parameter//
34 +
35 +
36 +[[image:CIM type.png]]
37 +
38 +//Figure 2 - Name of IMPACT CIM Type parameter//
39 +
40 +
41 +== IMPACT CIM Mark ==
42 +
43 +This is a parameter that marks the CIM with a number in the IMPACT database. The same CIM number can be found in IMPACT Standard Admin and CIM definitions in IMPACT AutoCAD.
44 +
45 +IMPACT CIM Mark is the parameter that a user must use to make a connection between Revit CIM family and AutoCAD CIM block. If the element is saved in IMPACT Revit and later on generated in an IMPACT AutoCAD drawing, a CIM with the same number will be generated on the AutoCAD drawing.
46 +
47 +[[image:IMPACT CIM mark.png]]
48 +
49 +//Figure 3 - MPACT CIM Mark//
50 +
51 +
52 +[[image:name of cims in standard admin.png]]
53 +
54 +//Figure 4 - IMPACT CIM Mark corresponds to the Cast-in Materials numbers, shown in IMPACT Standard Admin//
55 +
56 +
57 +[[image:acad name of cims.png]]
58 +
59 +//Figure 5 - IMPACT CIM Mark corresponds to the Cast-in Materials numbers, shown in CIM definitions in IMPACT AutoCAD//
60 +
61 +Read also about possibility for creating Project CIM.
62 +
63 +
64 +== IMPACT Schedule ==
65 +
66 +IMPACT Schedule parameter is used for differentiating between automatically generated shedules on the shop drawing. For example if the parameter has a value ´´cim´´, the CIM will be included in the CIM schedule, that is generated automatically on the shop drawing.
67 +
68 +The same parameter is also used with value´´opening´´ in recess families. The recesses are then included in automatically generated opening schedules on the IMPACT Revit shop drawing.
69 +
70 +[[image:IMPACT Schedule.png]]
71 +
72 +//Figure 6 - IMPACT Schedule parameter//
73 +
74 +
75 +== Unique Mark Controller ==
76 +
77 +This parameter is necessary for user, that would like to keep same element mark on elements with identical geometry, component and reinforcement. This setting is available in the project properties in Project manager.
78 +
79 +Unique Mark Controller helps the IMPACT system to scan and identify elements with identical components, like for exampel CIM. Therefore, we advise the user to add Unique Mark Controller parameter to all newly-created CIM families. There is no need to fill in a value, as the value will be filled in automatically by the software, if needed.
80 +
81 +[[image:Unique Mark Controller.png]]
82 +
83 +//Figure 7 - IMPACT Unique Mark Controller.//
84 +
85 +
86 += //Additional parameters// =
87 +
88 +There are many additional parameters that are not necessary for CIM families, but the user can find them useful. Here we list some of the most used among the IMPACT users.
89 +
90 +
91 +== IMPACT CIM Reference ==
92 +
93 +The user can give various text values to the IMPACT CIM reference parameter. In the example below, the user has chosen to make a reference for the company, producing the CIM component. The parameter value will be displayed in the automatically generated Cast-in Material schedule in the IMPACT Revit shop drawing. The user can find IMPACT CIM Refence parameter in Standard Admin and in CIM deifinition in IMPACT AutoCAD
94 +
95 +[[image:IMPACT CIM reference.png]]
96 +
97 +//Figure 8 - IMPACT CIM Reference//
98 +
99 +[[image:impact cim reference in standard admin.png]]
100 +
101 +
102 +//Figure 9 - IMPACT CIM Reference in IMPACT Standard Admin//
103 +
104 +
105 +== IMPACT CIM Treatment ==
106 +
107 +IMPACT CIM Treatment is an instance parameter, where the user can write down the necessary treatment for the CIM component. The parameter value will be displayed in the automatically generated Cast-in Material schedule in the IMPACT Revit shop drawing.
108 +
109 +[[image:IMPACT CIM treatment.png]]
1538737789324-994.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.NiklasPalmgren
Size
... ... @@ -1,0 +1,1 @@
1 +0 bytes
Content
1538737826781-645.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.NiklasPalmgren
Size
... ... @@ -1,0 +1,1 @@
1 +0 bytes
Content
CIM type.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.DesiBorisova
Size
... ... @@ -1,0 +1,1 @@
1 +0 bytes
Content
IMPACT CIM mark.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.DesiBorisova
Size
... ... @@ -1,0 +1,1 @@
1 +0 bytes
Content
IMPACT CIM reference.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.DesiBorisova
Size
... ... @@ -1,0 +1,1 @@
1 +0 bytes
Content
IMPACT CIM treatment.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.DesiBorisova
Size
... ... @@ -1,0 +1,1 @@
1 +0 bytes
Content
IMPACT CIM type.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.DesiBorisova
Size
... ... @@ -1,0 +1,1 @@
1 +0 bytes
Content
IMPACT Schedule.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.DesiBorisova
Size
... ... @@ -1,0 +1,1 @@
1 +0 bytes
Content
Unique Mark Controller.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.DesiBorisova
Size
... ... @@ -1,0 +1,1 @@
1 +0 bytes
Content
acad name of cims.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.DesiBorisova
Size
... ... @@ -1,0 +1,1 @@
1 +0 bytes
Content
impact cim reference in standard admin.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.DesiBorisova
Size
... ... @@ -1,0 +1,1 @@
1 +0 bytes
Content
name of cims in standard admin.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.DesiBorisova
Size
... ... @@ -1,0 +1,1 @@
1 +0 bytes
Content
Copyright 2018 StruSoft AB
Impact Documentation