Compact element control
Introduction
The Compact element control report contains information about the production period, project description, element mark, control name, approved date, etc.
Report Setup
General report setup. All the fields have to be filled if you need a sum row at the end of the page.
Page max X and Page max Y defined the maximum size of the report page.
The X-axis is the columns A, B, C etc. The Y-axis is the rows 1, 2, 3 etc.
Continuous Header Row defines in which row the header and footer start, and in this case, it starts from row 10.
Continuous Start Row (in this case from row 11) is where the main information starts and Continuous End Row (in this case until row 40) is where the main information ends.
If the last field is filled a summary for each page will be created at the end of the page.
Header setup:
Here is how the header is set up for this report.
As you can see we have different X and Y values for each field. This is done so the program knows where to put the specific information into the report.
As mention above, the continuous header starts at row 10 to row 10 in the Y direction.
Here are the fields that can be added to the Header and Footer:
Fields | Description |
DIVISION_NAME | |
FACTORY_NAME | |
PRODUCTION_DATE_FROM | |
PRODUCTION_DATE_TO | |
PRODUCTION_FACTORY | |
PRODUCTION_PERIOD | |
PROJECT | |
PROJECT_DESCRIPTION | |
PROJECT_NAME | |
REJECTED_INCLUDED |
Selection setup:
The standard setup for the selections.
Continuous setup:
The Continuous setup is where you set up all the information, in this case, about the Compact element control.
As you can see, here you define only one row because this row will be the basis for this report, from row 11 to 40 as shown further up.
The fields you can add to this section are listed below:
Fields | Description |
APPROVED_BY | |
APPROVED_DATE | |
BED_ROTATION | |
BED_X | |
BED_Y | |
BOUNDING_BOX_AREA | |
CAST_ID | |
CAST_NOTE | (New in Q2/2023) |
CAST_UNIT_NAME | |
CONTROL_NAME | |
CONTROL_STATUS | |
DIVISION_NAME | |
ELEMENT_BUILDING | |
ELEMENT_CONTROLS | |
ELEMENT_FLOOR | |
ELEMENT_ID | |
ELEMENT_MARK | |
ELEMENT_PHASE | |
ELEMENT_TYPE | |
EXTENSION_BACK | |
EXTENSION_BOTTOM | |
EXTENSION_FRONT | |
EXTENSION_LEFT | |
EXTENSION_RIGHT | |
EXTENSION_TOP | |
FACTORY_NAME | |
GROSS_AREA | |
HEIGHT | |
LENGHT | |
MASS | |
NET_AREA | |
P_CONTROL_ATTACHMENTS | (New in Q2/2023) - Each Attachment will be placed in a cell. The Cell size determines the size of the Attachment. The minimum cell size for PDFs is height = 0,75* and width = 1*. |
P_INSPECTIONS_ATTACHMENTS | (New in Q2/2023) |
PRODUCT | |
PRODUCTION_DATE | |
PROJECT_DESCRIPTION | |
PROJECT_NAME | |
PROJECT_TEXT_3 | |
SHIFT | |
STATUS | |
TOTAL_HEIGHT | |
TOTAL_LENGTH | |
TOTAL_WIDTH | |
VOLUME | |
WIDTH |
Print report
From Controls in Resource Manager
This report can be printed from Resource Manager as shown below.
From Cast Planning in Project Manager
This report can be printed from Project Manager as shown below.
From Planning in Resource Manager
This report can be printed from Resource Manager as shown below.