DWGCIMVIEWMAXROWS
This variable sets how many rows the CIM pictures should be distributed on.
This variable will be overwritten if “DWGCIMVIEWCIMGRPVIEW" is containing a group with more than one view, fx “4[1,2].
Then will there be 2 rows and the views will be at top of each other.
If the group contains all three views then there will be 3 rows.
If " DWGCIMVIEWMAXROWS" is empty there will be as many rows as there are CIM groups and views.
Example of the IMPACT default setting:
Variable | Type | Value |
---|---|---|
DWGCIMVIEWMAXROWS | 0 | 0 |
Example with a user default setting:
Variable | Type | Value |
---|---|---|
DWGCIMVIEWMAXROWS | 0 | 2 |
When a setting is changed in Standard Admin, the button "Refresh Settings and Properties" must be run for the changed settings to take place.
The settings in Standard Admin serves as default settings when creating a new shop drawing or a new section.
After the change, the drawing must be redrawn or updated.