Drawing Types

Last modified by Dennis Knudsen on 2024/02/27 11:18

New drawing types can be created from the beginning or copied from an existing one to make a new drawing type. For every drawing type there are properties that can be defined.

DT prop.gif

Figure 1: Drawing types properties

1523275279569-560.png

Figure 2: Drawing types properties

As seen above, the properties dialog is where the drawing type name, size, insertion, etc are given.

1523275371534-149.png

Figure 3: Size of head block

The specification consists of an AutoCAD block in scale 1:1 with attributes or specifications. These and the drawing type properties are described more in-depth in the separate element type block articles found here.

The blocks are located under ...\Standard\1100\1100\templates_drawings. 1100 must be replaced with your company number. 

You are also defining which drawing head shall be used for the drawing type (in the example above _uh_001.dwg is used). The drawing head is always placed in the upper right corner of the drawing.
1523275457818-101.png

Figure 4: Size of drawing head

The drawing head is also placed in the same folder ...\Standard\1100\1100\templates_drawings.

Attributes

Attributes can be added in all kinds of drawings, for example, element type drawings, general blocks, shop drawing blocks. The following table shows attributes that can be used in all drawings, shop drawings, for sandwich, hollowcore, formslab and doublewall drawings.

Attributes have to be written like in the tables below.

aaaa.png

When editing an attribute, the Tag field is the attribute name from the tables below and the prompt is the description for the attribute which can be filled if that is desired.

OFFICIAL

UNOFFICIAL

All Drawings

 

FACTORY

FABRIKSKONTO

PROJECT

ORDERNR

DRAWING

RITNR

TEXT_1

RITNING_TEXT1

TEXT_2

RITNING_TEXT2

TEXT_3

RITNING_TEXT3

TEXT_4

RITNING_TEXT4

TEXT_5

RITNING_TEXT5

TEXT_6

RITNING_TEXT6

DRAWING_TEXT_7

 

DRAWING_TEXT_8

 

DRAWING_TEXT_9

 

DESIGNED_BY

RITARE

DESIGNED_DATE

 

CHECKED_BY

HANDLAGGARE

APPROVED_BY

 

APPROVED_DATE

RITNING_RITNING_DATUM

DRAWING_SCALE

SCALE

DRAWING_SHEET

 

DRAWING_STATUS

STATUS

PRELIMINARY_DATE

STATUS_DATUM

DRAWING_TYPE

 

DRAWING_REVISION

REV

SALES_PROJECT 
PROJECT_MANAGER 
DRAWING_CATEGORY_NAME 
DRAWING_CATEGORY_DESCRIPTION 
LAST_REVISION_TEXT

 

FLOOR

 

BUILDING

 

PHASE

 
  

All Shop Drawings

 

ELEMENT_MARK

LITTERA

STYLE

 

GROUP

PRODUKTGRUPP

ELEMENT_TYPE

 

ELEMENT_DESCRIPTION

ELEMENT_TYPBETECKNING

PRODUCT

 

MATERIAL_CODE (not sandwich or double wall)

 

LENGTH

 

WIDTH

 

HEIGHT

ELEMENT_THICKNESS

MASS

ELEMENT_VIKT

MASS_T

ELEMENT_VIKT

MASS_KG

 

NET_AREA

NETTO_AREA

NET_AREA_INSULATION_M2

Added in IMPACT 17

GROSS_AREA

 

GROSS_AREA_INSULATION_M2

Added in IMPACT 17

BOUNDING_BOX_AREA_M2

 

BOUNDING_BOX_AREA_INSULATION_M2

Added in IMPACT 17

VOLUME, VOLUME_L (liter)

VOLYM

VOLUME_M3 (m3)

 

IMP_MATERIAL_NAME

 

IMP_MATERIAL_DESCRIPTION

 

IMP_ELEMENT_THICKNESS

 

NO_PIECES

ELEMENT_ANTAL

NO_PIECES_READY_FOR_PRODUCTION

 

TRANSPORT_ID

 

ELEMENT_ID

 

ELEMENT_MARK_CHANGED_DATE 

 

 

Sandwich

 

BOUNDING_BOX_AREA_INNER_PANEL_M2

Added in IMPACT 17

BOUNDING_BOX_AREA_OUTER_PANEL_M2

Added in IMPACT 17

GROSS_AREA_INNER_PANEL_M2

Added in IMPACT 17

GROSS_AREA_OUTER_PANEL_M2

Added in IMPACT 17

VOLUME_INNER_PANEL

VOLYM_ISKIVA

VOLUME_OUTER_PANEL

VOLYM_YSKIVA

VOLUME_INNER_PANEL_L

VOLYM_ISKIVA

VOLUME_OUTER_PANEL_L

VOLYM_YSKIVA

VOLUME_INNER_PANEL_M3

 

VOLUME_OUTER_PANEL_M3

 

VOLUME_CONCRETE_M3

 

VOLUME_CONCRETE_L

 

MASS_INNER_PANEL

VIKT_ISKIVA

MASS_OUTER_PANEL

VIKT_YSKIVA

MASS_INNER_PANEL_T

VIKT_ISKIVA

MASS_OUTER_PANEL_T

VIKT_YSKIVA

MASS_INNER_PANEL_KG

 

MASS_OUTER_PANEL_KG

 

NET_AREA_INNER_PANEL_M2

Added in IMPACT 17

NET_AREA_OUTER_PANEL_M2

Added in IMPACT 17

VOLUME_INSULATION_M3

 

VOLUME_INSULATION_L

 

IMP_MATERIAL_NAME_INNER

 

IMP_MATERIAL_NAME_INSULATION

 

IMP_MATERIAL_NAME_OUTER

 

IMP_MATERIAL_DESCRIPTION_INNER

 

IMP_MATERIAL_DESCRIPTION_INSULATION

 

IMP_ELEMENT_THICKNESS_INSULATION

 

IMP_MATERIAL_DESCRIPTION_OUTER

 

 

 

Hollow Core

 

ENDCAP_LEFT_NAME

 

ENDCAP_RIGHT_NAME

 

ENDCAP_LEFT_DESCRIPTION

 

ENDCAP_RIGHT_DESCRIPTION

 

ENDCAP_LEFT_PROPERTIES

 

ENDCAP_LEFT_PROPERTIES_1

 

ENDCAP_RIGHT_PROPERTIES

 

ENDCAP_RIGHT_PROPERTIES_1

 

 

 

Double Wall

 

VOLUME_PANEL1

VOLYM_SIDA1

VOLUME_PANEL1_L

VOLYM_SIDA1

VOLUME_PANEL1_M3

 

VOLUME_PANEL2

VOLYM_SIDA2

VOLUME_PANEL2_L

VOLYM_SIDA2

VOLUME_PANEL2_M3

 

MASS_PANEL1

VIKT_SIDA1

MASS_PANEL1_T

VIKT_SIDA1

MASS_PANEL1_KG

 

MASS_PANEL2

VIKT_SIDA2

MASS_PANEL2_T

VIKT_SIDA2

MASS_PANEL2_KG

 

WIDTH_PANEL1

 

WIDTH_PANEL2

 

IMP_MATERIAL_NAME_PANEL_1

 

IMP_MATERIAL_NAME_PANEL_2

 

IMP_MATERIAL_DESCRIPTION_PANEL_1

 

IMP_MATERIAL_DESCRIPTION_PANEL_2

 

IMP_RC_MESH_COVER_PANEL_1

 

IMP_RC_MESH_COVER_PANEL_2

 

 

 

Form Slab

 

SLAB_RC_BAR_COVER

 

SLAB_RC_STRAND_COVER

 

SLAB_RC_MESH_COVER

 

SLAB_THICKNESS

 

AS1

 

AS2

 

Table 1: Drawing attributes

Specifications

The user defines their own values when using specifications, this process is described in Specifications.
The values that are available can then be assigned to the particular drawing type, this will be shown below.

Fields and options

When the specifications are set up, these are meant to be used for the specific drawing types. For specific drawing types, for example for, D Solid Slab, new fields can be added and only fields that were previously added under Specifications can be selected here. 

11q.png

Figure 5: Solid slab fields

Under Options, the fields for each drawing type are chosen again and this time in the next row multiple options can be written for each field name. 

Note: Field name under Options need to be added under Fields as well in order for it to be shown in Project Manager

options2.png

Figure 6: Options for solid slabs

Below it is showed how it looks 

GIF PM.gifGIF PM.gif

GIF 1: Properties -> Specification found when right-clicking on a drawing in Project Manager

The final step is to apply the template and see the result in CAD. 

custom11.png

Figure 7: Generating of a shop drawing

custom111.png

Figure 8: Defined values from Standard Admin and Project Manager showed in CAD

Tags:
Copyright 2024 StruSoft AB
IMPACT Wiki