CUT_BARS_USING_CIM_SIZE_DATA
Either use definition values or block bounding box when cutting bars for (Cast in material) CIM in bar mesh for FormSlab and DoubleWall. Default (0) used the block bounding box and (1) uses the CIM data.
In this example, the production setting "Move from small holes and cims" was unticked so the reinforcement will not move.
When the CIM is placed the reinforcement proposal is run to get the bars adjusted in regard to the CIM.
The distance is calculated as follows for the default setting (block bounding box):
145 mm which is the block bounding box for the CIM 0804, ceiling box.
25 mm is the cover set for the definition.
145/2 + 25 = 97.5 which is rounded up to 98 mm. (See the default example)
The custom value is set to 200 for the CIM and therefore the distance is as follows:
200/2 + 25 = 125 mm. (See the custom example)
Example of the IMPACT default setting:
Variable | Type | Value |
---|---|---|
CUT_BARS_USING_CIM_SIZE_DATA | 0 | 0 |
Example with a user default setting:
Variable | Type | Value |
---|---|---|
CUT_BARS_USING_CIM_SIZE_DATA | 0 | 1 |