Release notes IMPACT for AutoCAD & BricsCAD 16.0.009

Last modified by Dennis Knudsen on 2020/11/27 14:27

New

New: Warn if the amount of lift points for FormSlab is less than required. (Case 92841)
New: Variable "MEPKEYHEIGHTFROMSOLID" added so the MEP-Key follows the "Edge" of the geometry. (Case 90616)
New: The Variable "MEPKEYSHOWCIMREFERENCE" set the reference as the item text on MEP-Keys. (Case 92042)
New: Solid slabs has new blocks for mould side symbol in the sections. For up in mould _uTopSymbolSlab.dwg and down  _uBottomSymbolSlab.dwg. For Prestressed Solid Slab they are called _uTopSymbolPreSlab.dwg and _uBottomSymbolPreSlab.dwg. (Case 95769)
New: Show strands on shop drawings for Prestressed Slabs. The slabs needs to be redrawn. (Case 95772)
New: Section outside of the element on shop drawing implemented for slabs. (Case 94050)
New: Reinforcement to cast in materials for slabs and prestressed slabs. (Case 36603)
New: Possible to move and then mto core fillings connected to lifts and manually added core fillings on shop drawings for Hollowcores. (Case 93710)
New: Possibility to dimension straight bars in RGgroup when there are more than 4 bars in the group and the middle bar is off-center. (Case 92900)
New: Option to select which mold side symbols are shown in the shop drawing. (Case 94186)
New: New reinforcement setting, "MTO_SHOW_PRIMARY_SECONDARY_FORMSLAB", for FormSlabs to define if the primary and secondary bars sholud be in the reinforcement specification or not. (Case 93938)
New: New attribute UNITECHNIKUSECIMSIZEFORMOUNTPARTINSERTIONPT added. (Case 95823)
New: Linear- and Dynamic CIM can now be drawn on their own separate layers on the floor plan drawing. (Case 41884)
New: Freeze elevation added to shop drawings for walls. (Case 92023)
New: Edit Prestressed Slab should show the biggest and the smallest width of the slab to easier place the strands. (Case 95773)
New: Copy from "By User" to a strand pattern for Prestress slabs. (Case 95770)
New: Block for alert texts on shop drawings for FormSlab. (Case 88754)

Fix

Fix: When using a customized UCS and generating elements, the UCS will reset to normal UCS. (Case 93678)
Fix: Wall ties area with <None> is excluded from the wall tie schedule. (Case 92846)
Fix: Wall ties are added on the same line in the wall tie schedule if the data is the same. (Case 92843)
Fix: Vertical dimension for columns wasn't shown correct. (Case 95751)
Fix: Tolerance increased from 100 mm to 250 mm in shop drawings. (Case 93445)
Fix: The dimension measures of strand groups in Prestressed slabs depends on the scale of the section. (Case 95794)
Fix: Special case, where hollowcore slabs were not cut on the cutting zones. (Case 97217)
Fix: Special case where there were two numbers a the dimension line. (Case 75767)
Fix: Special case where the wall section didn't show all the straight bars in a reinforcement group. (Case 93940)
Fix: Special case where the slab section view wasn't drawn correct. (Case 94116)
Fix: Special case where the preview of the shape codes was not visible in ACAD. (Case 97221)
Fix: Special case where the extension of cast-in materials in slabs where calculated incorrect. (Case 97008)
Fix: Special case where the element mark text length was working strange on floor plan. (Case 93782)
Fix: Special case where the dimension was incorrect on a circular column. (Case 94004)
Fix: Special case where the dimension number wasn't show in the table of CIMs. (Case 94045)
Fix: Special case where the bars in bar mesh got rejected when generating the bar mesh but not when doing a producibility check. (Case 92875)
Fix: Special case where the "Step to next" button copied the endcap to the next slab segment. (Case 94126)
Fix: Special case where switching between CIM groups didn't work. (Case 92785)
Fix: Special case where one wall where drawn over another one or close to it and the lift moved from one wall to the other. (Case 94361)
Fix: Special case where configuring an existing reinforcement group didn't work properly. (Case 98592)
Fix: Special case where additional bars where coming in the 3D solid for walls on shop drawing. (Case 95734)
Fix: Special case where a mirrored symmetrical wall didn't get the same element mark when saving. (Case 94257)
Fix: Special case in definitions dialogs with long lists, many rows, shows wrong row when tabbing to second column in the list. (Case 96946)
Fix: Resolved issue where some rebars around openings were not tagged in sections. (Case 93439)
Fix: Resolved issue when switching settings for linear Cast-in Materials. (Case 72143)
Fix: Resolved an issue where the weep holes were inserted on top of the recesses. (Case 97519)
Fix: Resolved an issue where the inner side of the Linear Cast-in-material was represented as a continuous line when running Plot command. (Case 97583)
Fix: Resolved an issue where the dimension lines for MEP keys were not extended. (Case 95788)
Fix: Resolved an issue where the core fill was misplaced when inserting lifts in Hollow core. (Case 97489)
Fix: Resolved an issue where Reinforcement text was clashing. (Case 93873)
Fix: Resolved an issue where it was not possible to have empty spaces in the Shop drawing name. (Case 94088)
Fix: Resolved an issue where Bracing was inserted in a wall which did not have Bracing in the definition. (Case 93573)
Fix: Resolved a case where long dimension lines were generated on Shop Drawing after adding a horizontal section. (Case 96976)
Fix: Reinforcement template for slabs didn't add single rebars. (Case 95747)
Fix: Optimize performance for the preview dialogs. (Case 94233)
Fix: Not possible to edit rectangular Prestressed slab width on multiple elements. (Case 94626)
Fix: Multiple execution of draw weep holes on shop drawing resulted in duplicates. (Case 97554)
Fix: Mesh bars losing bars in some cases when edited. (Case 95902)
Fix: MEP-key will be placed in correct position after using functions "Edit MEP-key"  and and"MTO CIM". (Case 94193)
Fix: Insert linked bottom is now inserted correctly. (Case 92705)
Fix: Incorrect ribbon menu " Set Erection Sequence" has been removed from IMPACT for AutoCAD/BricsCAD. (Case 93611)
Fix: If disconnect reinforcement is selected directly when the cast in material is drawn it doesn't wok. (Case 96939)
Fix: Endcap reinforcement for slabs is missing the text for straight bars and is not drawing reinforcement for edges with multiple endcaps. (Case 93622)
Fix: Drawings are not automatically saved with Generate/Update plan/elevation and save element on floor plans and elevations in AutoCAD 2021. (Case 93815)
Fix: Draw Cast in material on floor plan for slabs with depth placement top ends up in bottom of slab on shop drawing. (Case 93621)
Fix: Doublewalls height resets to 0 when changing properties for multiple walls. (Case 97515)
Fix: Doublewall element becomes corrupted when updating a shop drawing or setting the elementmark. (Case 96966)
Fix: Dimension of radius in edge is missing for FormSlab. (Case 93270)
Fix: Defaultvalue create new CIM should have MTO checked and Level of detail 4 3D and it should remember last input in same session. (Case 93456)
Fix: CIMs in slabs now cuts the correct mesh. (Case 97573)
Fix: BricsCAD, unable to simultaneously access the database and read elements from the drawing for the command "Update Elevation". (Case 94670)
Fix: BricsCAD issue where Columns and beams in dwg were loosing connection to database when updated if non-Impact file (Drawing1.dwg) was already open in BricsCAD. (Case 98692)
Fix: AutoCAD commands should execute even if user doesn't have read access to transport planning data. (Case 90829)
Fix: Adding a recess to a slab and saving it changes the outer geometry. (Case 98781)