IMPACT for AutoCAD & BricsCAD - Version 17.0.016 Q4/2023
New
New: variable to set the text size for area mesh in shop drawings. (Case 128482)
New: The bending of the bar mesh could be predefined for each endcap component. (Case 128059)
New: Switch off the bent part of the bar mesh so it is not included in the bending schedule. (Case 129809)
New: Support for BricsCAD V24. (Case 128634)
New: Show reinforcement bar thickness in sections by default. (Case 127838)
New: Producibility control - loose bars missing Construction part should be excluded from the control. (Case 129534)
New: Possibility to stretch bars in bar mesh. (Case 128749)
New: Possibility to store reinforcement flection data for Unitechnik. (Case 128385)
New: Possibility to split bars in bar mesh. (Case 128757)
New: Possibility to remove single recesses, openings, corbels from elements drawn as solids. (Case 128312)
New: Possibility to remove bends from multiple bars. (Case 128756)
New: Possibility to move bar with grid in bar mesh. (Case 128750)
New: Possibility to modify the solid of Linked element. (Case 128846)
New: Possibility to join bars in bar mesh. (Case 128758)
New: Possibility to hatch the non cut zones of Hollow Core elements on the floor plan. (Case 127922)
New: Possibility to flip detail section arrows, note this requires new dwg files. (Case 128379)
New: Possibility to copy bends from one bar to others. (Case 128755)
New: Possibility to copy bar with grid in bar mesh. (Case 128614)
New: Possibility to add reinforcement to CIM for Hollow Core. (Case 129305)
New: New command for disconnecting reinforcement from Cast-in Materials. (Case 127931)
New: MTO Settings on duct Total length (default) and Unit length (new). Case 128912
New: More complex shapes of stairs are now supported. (Case 129187)
New: It is now possible to control the text height for endstop text. (Case 129163)
New: Improvements to Project Filter for Components. (Case 128532)
New: Implement "Specify On-screen (Once)" for drawing recess in element. (Case 129678)
New: Implement "Specify On-screen (Once)" for draw CIM in element. (Case 128910)
New: File Sync Skip files according to the Project Properties settings. (Case 128686)
New: Endcap filter added in Project Properties. (Case 121714)
New: Changed implementation of the recess height of Stairs to remaining height. (Case 128848)
New: Added a new presentation view 44 for the bar mesh on slabs and walls. (Case 128061)
New: Add the text "x4" after an opening (on the shop drawing) that uses the same endcap on all four edges. (Case 128937)
New: Add an individual setting for the Centre of gravity for each element type. (Case 128855)
New: "Back" view added to insert linked views on shop drawing. (Case 128913)
Fix
Fix: The project property, "Base elevation" for recesses didn't work. (Case 130054)
Fix: The minimum value for transverse and longitudinal bars should include the extra length added by the bend for bended bar mesh. (Case 129481)
Fix: Stretching a slab shouldn't ask if lifts should be updated if there are no lifts to be updated. (Case 128973)
Fix: Special case where the wall section wasn't drawn correct. (Case 128130)
Fix: Special case where the extents of a Linear Cim wasn't drawn correct. (Case 129015)
Fix: Special case where the barmark text wasn't shown in the sections. (Case 127937)
Fix: Special case where straight bars weren't show correct in the beam section. (Case 129708)
Fix: Special case where some recess properties were enabled when they shouldn't be. (Case 128310)
Fix: Special case where panel thickenings wasn't drawn correctly when generating shop drawing. (Case 130454)
Fix: Special case where MEP key was not displayed correctly based on normal and opposite side position in the wall. (Case 130109)
Fix: Special case where changing width of multiple Hollow Core elements didn't work properly. (Case 130507)
Fix: Special case where an endcap in recess didn't work. (Case 130289)
Fix: Special case where a weep hole wasn't placed the required distance from a recess. (Case 129683)
Fix: Special case where a wall section was missing for an unique opening. (Case 128123)
Fix: Special case where a gable wall weren't drawn correctly on elevation. (Case 128315)
Fix: Special case where "show Hidden Geometry" in the sections wasn't working. (Case 129690)
Fix: Special case where "Draw Cast-in Material from" didn't place the Cast-in Material correct. (Case 130141)
Fix: Special case where "Bend bars" command didn't work properly. (Case 130143)
Fix: Shop drawing text font is now taken from TEXTSTYLE as it did in IMPACT 16 when redrawing. (Case 130138)
Fix: Resolved the issue where reinforcement was misplaced in section view after taking MTO. (Case 130402)
Fix: Recess in MEP keys are not exported to Unitechnik for Sandwich and Solid Walls. (Case 130532)
Fix: Inserting multiple Linked elements didn't work. (Case 130247)
Fix: Generating shop drawings with bar mesh from floor plan didn't move bars away from CIMs. (Case 130063)
Fix: Generate shop drawings doesn't update the volumes for the endcap material. (Case 128307)
Fix: Formslab - Reinforcement doesn't get updated with definition change. (Case 129884)
Fix: Draw/Edit Wall Ties didn't support negative elevations. (Case 129580)
Fix: Draw slab didn't work from the ribbon if only one slab type where turned on. (Case 128657)
Fix: Draw CIM in Double Wall should use the last settings. (Case 129778)
Fix: Double-click on openings has been disabled since it in some cases could cause AutoCAD to crash. (Case 128936)
Fix: Double wall should follow project property "Element mark rotation". (Case 129681)
Fix: Cut in Reinforcement template when using Bar mesh. (Case 130114)
Fix: "Delete on both systems" components get downloaded with "Edit and Sync". (Case 128699)
Change
Change: Draw endcap view icon moved to the Endcap dropdown menu. (Case 127794)