Version 17.0.011 Q3/2023

Last modified by Dennis Knudsen on 2023/09/26 08:09

New

New: DWI and DWG files connected to Linked elements should be synced when created or updated in CAD on cloud sync project. (Case 125588)

New: Possibility to assign endcaps to recess segments. (Case 124529)

New: RC group mass added to the RC group mark in the lineup. (Case 126475)

New: Dimension settings for the location of the dimension lines depending on the side of the components has been added for each type of element. (Case 122392)

New: Possibility to only add bracing anchors in command "Generate Braces". (Case 126293)

New: Stairs as linked elements are supported in BricsCAD V23.2.05. (Case 126800)

New: The "Element" ribbon has been extended with the command "Visibility control" in the "Reinforcement" panel. (Case 126774)

New: The "Element" ribbon has been extended with typical shop drawing commands in the new "Drawings" panel. (Case 126773)

New: Change the storing of Hollowcore endcaps, K-edges. (Case 126551)

New: Draw Erection material on elevation and get it label and specified. Also bring it to the model drawing. (Case 46918)

New: Implement "Draw Cast-in Material from..." on elevation drawings. (Case 126881)

New: Reinforcement template for walls now supports shape code "51" in wall beams and wall columns. (Case 127245)

New: sorting in autocad for specifications takes groups priority. (Case 126482)

New: Possibility to copy section arrows in the drawing view for reinforcement groups. (Case 127054)

New: Delete element from database prompt changed to "Erase element id from Database". (Case 127792)

New: Endcap reference on openings for walls on elevation and shop drawings for openings with the same endcap are not placed optimally. (Case 127373)

New: Line-up MEP key that only shows the MEP keys used in the project and shows the element information as the line-up endcap. (Case 124727)

New: Possibility to change the start point when generating grid lines in the elevation drawing. (Case 124783)

New: Possibility to see fillings in IFC export. (Case 126374)

New: Remark attribute added to drawing blocks. (127399)

New: Send lattice girders in Sandwich walls to Unitechnik as BRGIRDER. Requires both dynamic cim and lattice girder data on the cast in material. (Case 127181)

New: Viewer for the producibility check of bar mesh and tooltip of the result on the bars not passing the control. Several new commands for adjusting the bar mesh. (Case 127298)

Fix

Fix: Project title is not shown in definition. ( Case 126400)

Fix: Annotation text is not automatically filled in when choosing a Material. (Case 126555)

Fix: Turn invisible recess on/off in main view is not working anymore returns unknown command. (Case 126930)

Fix: Dimension type changed to "Edge" even if not selected. (Case 127146)

Fix: If I insert a linked element that is missing a dwg file IMPACT create an wireframe dwi file of the element it should be a soild of the element instead. (Case 127090)

Fix: Special case where the rounding of reinforcement measure wasn't correct. (Case 127003)

Fix: Draw Hanger detail all components ends up in same slab. (Case 126694)

Fix: Reinforcement that has a multi segment distribution line are not shown correct in sections. (Case 127359)

Fix: Special case where a linear cim was not shown correct in a detail section. (Case 127438)

Fix:  When the setting "Reinforcement view for each panel" in project properties was set to NO the mesh was drawn wrongly for the inner panel in the reinforcement view. (Case 128011)

Fix: Draw recess - height defined in elevation & shop drawings makes the value lock with the specific value. (Case 127996)

Fix: Half-scale setting set to "No" is causing wrong size of the insulation. (Case 127984)

Fix: Possibility to override the horizontal section view direction for walls with cast type "Battery". (Case 127868)

Fix: Reinforcement in form slabs didn't get updated correctly when switching definition. (Case 128305)

Fix: Special case where a floor plan couldn't open in BricsCAD. (Case 128220)

Fix: Special case where the bar mesh wasn't cut correct by the element boundary. (Case 127658)

Fix: Special case where the depth of ducts wasn't shown correct on the elevation. (Case 127997)

Fix: Special case where the reinforcement group 3d view was offset. (Case 127599)

Fix: Special case where weep hole was placed incorrect. (Case 128304)

Fix: Unsaved element color is applied for both the element mark and the outline (geometry) in elevation drawings. (Case 128016)

Fix: When copying a reinforcement group second time then it can not be selected. (Case 127561)