IMPACT for AutoCAD & BricsCAD - Version 17.1.001 Q1/2024
New
New: Possibility to export stirrups of the following shape codes to Unitechnik B, C, S and N. (Case 131770)
New: "Start", "End" and "Main" types added to Reinforcement Groups. (Case 127380)
New: Add a new attribute “LAST_REVISION_TEXT” and when drawing is revised set approved date to same as the latest revision. (Case 129413)
New: Add Drawing Category to the Edit drawing panel command. (Case 129182)
New: Add three more drawing attributes “DRAWING_TEXT_7”, “DRAWING_TEXT_8” and “DRAWING_TEXT_9” to the drawing panel. (Case 129412)
New: Add total amount of an Electrical key to the Project Line up MEP key. (Case 128938)
New: Add two new attributes DRAWING_CATEGORY_NAME and DRAWING_CATEGORY_DESCRIPTION to connect Drawing Category information to the drawing panel. (Case 129181)
New: Added a button to show production setting errors without running the producibility check. (Case 130997)
New: CIM dimension line is now added to both vertical and horizontal sections for both walls and slabs. (Case 130999)
New: Command "Replace Bars" added to ribbons "Doublewall", "Formslab" and "Element". (Case 130527)
New: L-shape bars is added as edge reinforcement in the reinforcement template for walls. (Case 130624)
New: More colors defined as black in the plot color tables IMPACT, IMPACT_Halv, IMPACT_100 and IMPACT_70.ctb. (Case 131166)
New: Possibility for one line dimension for all MEP Keys on the shop drawing. (Case 130632)
New: Possibility to setup default alignment for Prestressed Slabs in the definition. (Case 128775)
New: Production settings added for bended mesh. (Case 129735)
New: Reinforcement bar in joint as erection material. (Case 130629)
New: Separate the panel thickening concrete as we do with the material in the endcap. Variable SHOWPANELTHICKENINGPROPSSEPARATE set to 1 in SA to turn it on (Case 130660)
New: Show depth placement (CIM) is missing from joints. (Case 125593)
Fix
Fix: "Visible" Element types is now reflected into the export unitechnik filter. (Case 131358)
Fix: A new Cast-in Material wasn't listed in alphabetical order in the "Draw Cast-in Material" dialog. (Case 130634)
Fix: Adjust to minimum/maximum bar projection not extending to minimum. (Case 131075)
Fix: BAR_MESH_BENDING_DETAIL_SCALE didn't work. (Case 131506)
Fix: Command "Generate plan" didn't show holes in form slabs when generating solid. (Case 131871)
Fix: Design status is not updated on generate shop drawing and batch generate. (Case 130681)
Fix: Dimension extents for cast in materials in linked elements doesn't work. (Case 131819).
Fix: Dimension number for dynamic and linear cast-in materials missing in section. (Case 130762)
Fix: Draw recess in the bottom of the element didn't behave as expected. (Case 130544)
Fix: Fixed the issue where some options in reinforcement template were not greyed out. (Case 131437)
Fix: Issue with "Save As" and locking of drawing in a file sync project. (Case 130556)
Fix: Issue with MEP key items on the opposite side. (Case 130483)
Fix: LINKED_E layer missing in SA. (Case 130612)
Fix: Reinforcement does not align correctly in the bar mesh drawing view when the wall has been rotated 90 degrees. (Case 131523)
Fix: Setting element mark will skip any element mark already in use by another element type. (Case 131701)
Fix: Show depth in annotation text is activated even when it is not selected. (Case 130937)
Fix: Special case where "Draw cast-in material from" didn't work properly on elevation. (Case 131979)
Fix: Special case where "Draw stair" failed. (Case 131269)
Fix: Special case where a recess wasn't drawn correct for a beam. (Case 131072)
Fix: Special case where bending a bar didn't work properly. (Case 132067)
Fix: Special case where stretching element on elevation creates an instance in other endcap on floor plan but not on elevation. (Case 131406)
Fix: Special case where the bar mesh not displayed correct in the sections. (Case 131451)
Fix: Special case where the bar mesh was not cut by the MEP-Key component. (Case 131658)
Fix: Special case where the bended mesh wasn't shown correctly in the section. (Case 130442)
Fix: Special case where the producibiliy check didn't show tool tip. (Case 131642)
Fix: Special case where the reinforcement group drawing view wasn't drawn correct. (Case 131801)
Fix: Staggered barmarks not correctly drawn in the solid drawing view. (Case 131855)
Fix: Stretch bars shouldn't stretch invisible bars. (Case 131825)
Fix: The bar mesh drawing view wasn't updated when doing MTO Reinforcement. (Case 131028)
New: The reinforcement template for walls now include corner reinforcement. (Case 35277)