IMPACT for AutoCAD & BricsCAD - Version 17.1.001 Q1/2024

Last modified by Oskar Kristinsson on 2024/03/05 09:28

New

New:  Possibility to export stirrups of the following shape codes to Unitechnik B, C, S and N. (Case 131770)

New: "Start", "End" and "Main" types added to Reinforcement Groups. (Case 127380)

New: Add a new attribute “LAST_REVISION_TEXT” and when drawing is revised set approved date to same as the latest revision. (Case 129413)

New: Add Drawing Category to the Edit drawing panel command. (Case 129182)

New: Add three more drawing attributes “DRAWING_TEXT_7”, “DRAWING_TEXT_8” and “DRAWING_TEXT_9” to the drawing panel. (Case 129412)

New: Add total amount of an Electrical key to the Project Line up MEP key. (Case 128938)

New: Add two new attributes DRAWING_CATEGORY_NAME and DRAWING_CATEGORY_DESCRIPTION to connect Drawing Category information to the drawing panel. (Case 129181)

New: Added a button to show production setting errors without running the producibility check. (Case 130997)

New: CIM dimension line is now added to both vertical and horizontal sections for both walls and slabs. (Case 130999)

New: Command "Replace Bars" added to ribbons "Doublewall", "Formslab" and "Element". (Case 130527)

New: L-shape bars is added as edge reinforcement in the reinforcement template for walls. (Case 130624)

New: More colors defined as black in the plot color tables IMPACT, IMPACT_Halv, IMPACT_100 and IMPACT_70.ctb. (Case 131166)

New: Possibility for one line dimension for all MEP Keys on the shop drawing. (Case 130632)

New: Possibility to setup default alignment for Prestressed Slabs in the definition. (Case 128775)

New: Production settings added for bended mesh. (Case 129735)

New: Reinforcement bar in joint as erection material. (Case 130629)

New: Separate the panel thickening concrete as we do with the material in the endcap. Variable SHOWPANELTHICKENINGPROPSSEPARATE set to 1 in SA to turn it on (Case 130660)

New: Show depth placement (CIM) is missing from joints. (Case 125593)

Fix

Fix: "Visible" Element types is now reflected into the export unitechnik filter. (Case 131358)

Fix: A new Cast-in Material wasn't listed in alphabetical order in the "Draw Cast-in Material" dialog. (Case 130634)

Fix: Adjust to minimum/maximum bar projection not extending to minimum. (Case 131075)

Fix: BAR_MESH_BENDING_DETAIL_SCALE didn't work. (Case 131506)

Fix: Command "Generate plan" didn't show holes in form slabs when generating solid. (Case 131871)

Fix: Design status is not updated on generate shop drawing and batch generate. (Case 130681)

Fix: Dimension extents for cast in materials  in linked elements doesn't work. (Case 131819).

Fix: Dimension number for dynamic and linear cast-in materials missing in section. (Case 130762)

Fix: Draw recess in the bottom of the element didn't behave as expected. (Case 130544)

Fix: Fixed the issue where some options in reinforcement template were not greyed out. (Case 131437)

Fix: Issue with "Save As" and locking of drawing in a file sync project. (Case 130556)

Fix: Issue with MEP key items on the opposite side. (Case 130483)

Fix: LINKED_E layer missing in SA. (Case 130612)

Fix: Reinforcement does not align correctly in the bar mesh drawing view when the wall has been rotated 90 degrees. (Case 131523)

Fix: Setting element mark will skip any element mark already in use by another element type. (Case 131701)

Fix: Show depth in annotation text is activated even when it is not selected. (Case 130937)

Fix: Special case where "Draw cast-in material from" didn't work properly on elevation. (Case 131979)

Fix: Special case where "Draw stair" failed. (Case 131269)

Fix: Special case where a recess wasn't drawn correct for a beam. (Case 131072)

Fix: Special case where bending a bar didn't work properly. (Case 132067)

Fix: Special case where stretching element on elevation creates an instance in other endcap on floor plan but not on elevation. (Case 131406)

Fix: Special case where the bar mesh not displayed correct in the sections. (Case 131451)

Fix: Special case where the bar mesh was not cut by the MEP-Key component. (Case 131658)

Fix: Special case where the bended mesh wasn't shown correctly in the section. (Case 130442)

Fix: Special case where the producibiliy check didn't show tool tip. (Case 131642)

Fix: Special case where the reinforcement group drawing view wasn't drawn correct. (Case 131801)

Fix: Staggered barmarks not correctly drawn in the solid drawing view. (Case 131855)

Fix: Stretch bars shouldn't stretch invisible bars. (Case 131825)

Fix: The bar mesh drawing view wasn't updated when doing MTO Reinforcement. (Case 131028)

New: The reinforcement template for walls now include corner reinforcement. (Case 35277)