Release notes IMPACT Revit 16.0.024

Last modified by Dennis Knudsen on 2022/02/21 14:36

New

New: Warning message when the endstop can't be drawn for solid slabs and prestressed slabs. (Case 86329)
New: Update the Element mark in the Revit model when the Element mark has been renamed in IMPACT Project Manager. (Case 116855)
New: Show Center of Gravity for sloped elements. (Case 112912)
New: Possibility to add annotation text indicating the side of element on the CIM dimension lines in the shop drawing. (Case 111419)
New: It is now possible to map the Double wall definition. (Case 110271)
New: Endcap description is now shown in the Edit slab command. (Case 112016)
New: Draw Connection command for Slab elements. (Case 112962)
New: Draw Connection command for Prestressed Slab elements. (Case 112958)

Fix

Fix: Resolved issue where the sections were not shown properly. (Case 117958)
Fix: Resolved issue where shop drawings did not work as expected. (Case 117211)
Fix: Resolved issue where Revit files opened in a new instance instead of an active instance of Revit. (Case 103389)
Fix: Resolved issue where Revit crashed when loading specific families to dynamic CIM definition. (Case 117398)
Fix: Resolved issue where RC templates did not work properly for specific walls. (Case 117616)
Fix: Resolved issue where projects were unlinked when multiple standards were imported. (Case 117953)
Fix: Resolved issue where elements were not set to modified after adding/deleting components. (Case 117435)
Fix: Resolved issue where draw slabs according to zones did not work properly. (Case 110358)
Fix: Resolved issue where a specific endcap could not be added. (Case 117615)
Fix: Resolved issue in Smart CIM where front side was not correctly shown when the sandwich wall definition was set to 'Inner Panel Down'. (Case 112950)
Fix: Resolved an issue where updating shopdrawing didn't work. (Case 116616)
Fix: Performance improved while working in IMPACT Revit. (Case 114259)
Fix: Improved speed for connecting walls with joints. (Case 111080)
Fix: Fixed the issue where the holes were not having the correct size. (Case 116864)
Fix: Fixed an issue where the stairs were rotated in model view in Project Manager after saving them as Linked from Revit. (Case 116940)
Fix: Fixed an issue where the slabs were rotated in Project Manager after saving them from Revit. (Case 112905)
Fix: Fixed an issue where the slab definition could not be changed and additional lifts were inserted when editing the slab. (Case 112008 )
Fix: Fixed an issue where the Shop drawing generation failed. (Case 114427)
Fix: Fixed an issue where the reinforcement template could not be inserted into a specific wall. (Case 114401)
Fix: Fixed an issue where the Reinforcement series was not inserting all the rebars in angled slabs. (Case 116880)
Fix: Fixed an issue where the panel thickening could not be inserted when having a thickness less than 30mm. (Case 116804)
Fix: Fixed an issue where the endcaps were not inserted in specific openings. (Case 117111)
Fix: Fixed an issue where the endcap dimension text and lines were missing in the Shop drawing if the legend was deleted. (Case 111561)
Fix: Fixed an issue where the Drawing properties were disabled in Shop Drawing when having the Revit file extension .RVT with capital letters. (Case 117001)
Fix: Fixed an issue where the collaboration local file was not opened through Project Manager. (Case 117066)
Fix: Fixed an issue where the CIM was removed from element when splitting vertically. (Case 114262)
Fix: Assemblys moves after editing endcap. (Case 116783)