Version 17.1.001 Q1/2024

Last modified by Oskar Kristinsson on 2024/03/05 10:44

New

New: A new functionality that adds the possibility to rehost CIM and reinforcement in sandwich walls and double walls. (Case 130252)

New: Added a new parameter for the bended mesh, named "IMPACT Bended Mesh Shape Code". (Case 128995)

New: Added column in IMP_DRAWING table to store cloud file path (129870).

New: Adding IMPACT Host parameter in Parts. (Case 129574)

New: Change Slab Direction command added. (Case 126535)

New: CIM dimensions placed on left or top when set to closest edge. (Case 129106)

New: Corrected the spelling of the lattice girder family. (Case 129551)

New: Drawing parameter “IMPACT Drawing Last Revision´´ added. (Case 129411)

New: Fixed numbers on edge reinforcement. (Case 126544)

New: IMPACT Bar Mark parameter is populated with the name of the mesh. (Case 129573)

New: It is now possible to add user dimension text for cast-in-materials dimension lines. (Case 126526)

New: It is now possible to have user-defined families for lattice girders. (Case 125166)

New: It is now possible to insert profile mesh for slabs. (Case 126487)

New: It is now possible to select material when adding fillings for form slabs. (Case 129123)

New: It is now possible to set the hole distance to "0" when connecting double walls. (Case 129750)

New: MEP key dimension functionality added for Item and Recess in the MEP key definition window. (Case 129797)

New: Preserve manual reinforcement changes with  Insert  CIM command. (Case 129517)

New: Text 7, Text 8 and Text 9 new fields in New IMPACT Project window. (Case 131407)

New: The chamfer in a column is now removed from the part where the corbel is inserted. (Case 126521)

New: The field "A-placing cut" from Double wall definition is now enabled when Area is selected. (Case 130377)

New: The fields a1 and a2 from Sloped I shaped prestressed beam are now showing degree values. (Case 128353)

New: Three new drawing parameters “Text 7”, “Text 8” and “Text 9” are added to Drawing Properties. (Case 129410)

New: Use Fixed Number setting for rebars in Reinforcement in Endcaps. (Case 129129)

New: We are now showing one assembly in the Print function when the elements are the same. (Case 129603)

New; Category field added to the Drawing Properties functionality giving the possibility to edit the drawing category of the drawing. (Case 129178)

Fix

Fix: Dimension for opening that goes through the entire double wall should be added for both panels. (Case 130227)

Fix: Fixed the issue where could not pick a new face in element in order to place the bended mesh. (Case 129576)

Fix: Fixed the issue where the endcap was inserted in the opposite side of the element. (case 130164)

Fix: Fixed the issue where the values A and C of CIM placement were reversed when applying the joint. (Case 129145)

Fix: Linked element data is not displayed correctly. (Case 130648)

Fix: Performance issue when creating an opening. (Case 129912)

Fix: Reinforcement around opening is not inserted correctly in Double wall. (Case 130180)

Fix: Resolved issue where CIM Templates did not work properly when using CIM with rebars. (Case 129160)

Fix: Resolved issue where hangers did not work as expected for hollow core. (Case 129117)

Fix: Resolved the issue where a new mould symbol was inserted after  updating the Shop drawing. (Case 129782)

Fix: Resolved the issue where base height right and base height left values were wrong. (Case 130524)

Fix: Resolved the issue where the balcony slabs drawn as generic models were removed from model after connecting walls. (Case 129139)

Fix: Resolved the issue where the Representation preview of Panel 2 was not saved after closing the dialogue window. (Case 130379)

Fix: Resolved the issue where the title height value was not considered after generating the Shop drawing. (Case 130774)

Fix: Special case where the lattice girder spacing of double wall was not the same in model as in definition when drawing the double wall from Local level. (Case 129156)

Fix: Support length not shown correct in Form Slab. ( Case 130233)

Fix: The insertion point of the viewport name on the shop drawing sheet is not the same as in the shop drawing template. (Case 129155)

Fix: Transfer dimension settings between views in the shop drawing template. (Case 129203)

Fix: When adding recess to beam it is not inserted correctly or not at all (Case 130700)

Fix: Wrong placement of the Lift in Sandwich wall. (Case 130756)