Slab variables
Last modified by Adam Carlson on 2023/05/25 12:47
Below are the variables that affect slabs in IMPACT for AutoCAD
General
Variable | Short description | Default value |
DWGTEXTTOPSLAB | Controls the default annotation text for placement of components added to a slab - Top | T |
DWGSLABSUPRESSHATCHSECTION | Set to 1 to suppress/disable hatch patterns to be drawn for fillings in section views. Set to 0 to enable, or remove the variable completely. | 0 (Draw hatch) |
DWGTEXTHEIGHTENDCAPELEMSLAB | Sets the text height for the endcap in the shop drawing. The default value is 2.8*drawing scale. | 2.8 |
DWGSLABHORZSECTIONGAP | Sets the distance between two horizontal sections. The default value is 10*drawing scale. | 10 |
DWGSLABVERTSECTIONGAP | Sets the distance between two vertical sections. The default value is 10*drawing scale. | 10 |
DWGTEXTBOTTOMSLAB | Controls the default annotation text for placement of components added to a slab - Bottom | B |
DWGTEXTFRONTSLAB | Controls the default annotation text for placement of components added to a slab - Front | NF |
DWGTEXTBACKSLAB | Controls the default annotation text for placement of components added to a slab - Back | FF |
DWGTEXTLEFTSIDESLAB | Controls the default annotation text for placement of components added to a slab - Left side | LS |
DWGTEXTRIGHTSIDESLAB | Controls the default annotation text for placement of components added to a slab - Right side | RS |
DWGSLABHORZSECTIONCIMALL | Sets if "Include all cast-in materials" should be marked as default in the horizontal section | 0 |
DWGSLABHORZSECTIONCIMTOLERANCEAFTER | Sets the "tolerance after" value for the CIM, horizontal section | 200 |
DWGSLABHORZSECTIONCIMTOLERANCEBEFORE | Sets the "tolerance before" value for the CIM, horizontal section | 50 |
DWGSLABHORZSECTIONRCALL | Sets if "Include all reinforcement" should be marked as default in the horizontal section | 0 |
DWGSLABHORZSECTIONRCTOLERANCEAFTER | Sets the "tolerance after" value for the reinforcement, horizontal section | 10 |
DWGSLABHORZSECTIONRCTOLERANCEBEFORE | Sets the "tolerance before" value for the reinforcement, horizontal section | 10 |
DWGSLABVERTSECTIONCIMALL | Sets if "Include all cast-in materials" should be marked as default in the vertical section | 0 |
DWGSLABVERTSECTIONCIMTOLERANCEAFTER | Sets the "tolerance after" value for the CIM, vertical section | 200 |
DWGSLABVERTSECTIONCIMTOLERANCEBEFORE | Sets the "tolerance before" value for the CIM, vertical section | 50 |
DWGSLABVERTSECTIONRCALL | Sets if "Include all reinforcement" should be marked as default in the vertical section | 0 |
DWGSLABVERTSECTIONRCTOLERANCEAFTER | Sets the "tolerance after" value for the reinforcement, vertical section | 10 |
DWGSLABVERTSECTIONRCTOLERANCEBEFORE | Sets the "tolerance before" value for the reinforcement, vertical section | 10 |
DWGTEXTSTRANDGRP | Sets what text should be written next to the section for the strand group | 0 |
Solid slab
Variable | Short description | Default value |
ANNOTATIONBYMOULDSIDESOLIDSLAB | Changes the annotation of CIM:s, recesses, lifts, etc due to the cast type of the solid slab. | 0 |
AUTOCHECKPRODUCIBILITYSOLIDSLAB | Does a producibility check automatically without creating a Unitechnik file on the following commands:
| 0 |
AUTOEXPORTUNITECHNIKSOLIDSLAB | Exports a Unitechnik file automatically on the following commands:
| 0 |
SOLIDSLABSECTIONSCALE | Controls the slab section scale, if the value is set to 50 then the scale will be 1:50. Default value 1:20 | 1:20 |
DWGDIMFLOORPLANCUTSLAB | Enables a dimension of the width of the slab to be drawn inside the element when the width of the slab is less than the width specified in its definition. | 0 |
DWGSHOWSINGLESECTIONNAMESLAB | Enables letters on each section arrow | 0 |
DWGDIMSLABLIFT | Controls lift measurements of wide slabs | 1 |
Prestressed Solid slab
Variable | Short description | Default value |
AUTOCHECKPRODUCIBILITYPRESLAB | Does a producibility check automatically without creating a Unitechnik file on the following commands:
| 0 |
AUTOEXPORTUNITECHNIKPRESLAB | Exports a Unitechnik file automatically on the following commands:
| 0 |
DWGDIMFLOORPLANCUTPRESLAB | Enables a dimension of the width of the slab to be drawn inside the element when the width of the slab is less than the width specified in its definition. | 0 |
Controls lift measurements of prestressed wide slabs | 1 |
Hollow core
Variable | Short description | Default value |
HCSMINIMUMCUTGAP | Controls gap between hollow core elements | 0 |
DWGTEXTCONNECTIONRECESS | Text that is shown for the connection recess on the edge | R $S $L $W $H |
DWGTEXTCONNECTIONRECESSWIDTH | Text that is shown for the connection recess | R %%c$D |
DWGDIMFLOORPLANCUTHCS | Enables a dimension of the width of the slab to be drawn inside the element when the width of the slab is less than the width specified in its definition. | 0 |
DWGTEXTCORE | Prefix for the core number | C |
DWGTEXTCOREFILLING | A header for the core filling | CORE FILLING |
DWGTEXTHCSENDCAPCUTOUT | Text on the dimension line for a cut out in the endcap | R TC |
DWGTEXTHCSENDCAPRECESS | Text on the dimension line for a recess in the endcap | R T |
DWGTEXTHCSLIFTANNOTATION | A header for the lift | Core |
DWGTEXTHCSLIFTCOREANNOTATION | Prefix for the lift number | C |
DWGTEXTHCSENDCAPHOLE | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
DWGTEXTHCSENDCAPHOLE1 | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
DWGTEXTHCSENDCAPHOLEHOLE | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
DWGTEXTHCSENDCAPHOLEHOLE1 | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
DWGTEXTHCSENDCAPHOLETOP | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
DWGTEXTHCSENDCAPHOLETOP1 | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
DWGTEXTHCSENDCAPNONE | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
DWGTEXTHCSENDCAPNONE1 | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
DWGTEXTHCSENDCAPTOP | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
DWGTEXTHCSENDCAPTOP1 | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
DWGTEXTHCSENDCAPTOPHOLE | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
DWGTEXTHCSENDCAPTOPHOLE1 | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
DWGTEXTHCSENDCAPTOPTOP | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
DWGTEXTHCSENDCAPTOPTOP1 | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
DWGTEXTSECTIONSCALE | Strandpattern scale can be changed with this variable | 1:$SCALE |
DWGTEXTSTRANDPATTERN | Strandpattern description can be changed with this variable | $NAME |