Slab variables
Last modified by Dennis Knudsen on 2025/08/26 11:40
Below are the variables that affect slabs in IMPACT for AutoCAD
General
| Variable | Short description | Default value |
| DWGTEXTTOPSLAB | Controls the default annotation text for placement of components added to a slab - Top | T |
| DWGSLABSUPRESSHATCHSECTION | Set to 1 to suppress/disable hatch patterns to be drawn for fillings in section views. Set to 0 to enable, or remove the variable completely. | 0 (Draw hatch) |
| DWGTEXTHEIGHTENDCAPELEMSLAB | Sets the text height for the endcap in the shop drawing. The default value is 2.8*drawing scale. | 2.8 |
| DWGSLABHORZSECTIONGAP | Sets the distance between two horizontal sections. The default value is 10*drawing scale. | 10 |
| DWGSLABVERTSECTIONGAP | Sets the distance between two vertical sections. The default value is 10*drawing scale. | 10 |
| DWGTEXTBOTTOMSLAB | Controls the default annotation text for placement of components added to a slab - Bottom | B |
| DWGTEXTFRONTSLAB | Controls the default annotation text for placement of components added to a slab - Front | NF |
| DWGTEXTBACKSLAB | Controls the default annotation text for placement of components added to a slab - Back | FF |
| DWGTEXTLEFTSIDESLAB | Controls the default annotation text for placement of components added to a slab - Left side | LS |
| DWGTEXTRIGHTSIDESLAB | Controls the default annotation text for placement of components added to a slab - Right side | RS |
| DWGSLABHORZSECTIONCIMALL | Sets if "Include all cast-in materials" should be marked as default in the horizontal section | 0 |
| Sets if dimension line for cast-in materials on slabs' horizontal sections should be added. | 0 | |
| DWGSLABHORZSECTIONCIMTOLERANCEAFTER | Sets the "tolerance after" value for the CIM, horizontal section | 200 |
| DWGSLABHORZSECTIONCIMTOLERANCEBEFORE | Sets the "tolerance before" value for the CIM, horizontal section | 50 |
| DWGSLABHORZSECTIONRCALL | Sets if "Include all reinforcement" should be marked as default in the horizontal section | 0 |
| DWGSLABHORZSECTIONRCTOLERANCEAFTER | Sets the "tolerance after" value for the reinforcement, horizontal section | 10 |
| DWGSLABHORZSECTIONRCTOLERANCEBEFORE | Sets the "tolerance before" value for the reinforcement, horizontal section | 10 |
| DWGSLABVERTSECTIONCIMALL | Sets if "Include all cast-in materials" should be marked as default in the vertical section | 0 |
| Sets if dimension line for cast-in materials on slabs' vertical sections should be added. | 0 | |
| DWGSLABVERTSECTIONCIMTOLERANCEAFTER | Sets the "tolerance after" value for the CIM, vertical section | 200 |
| DWGSLABVERTSECTIONCIMTOLERANCEBEFORE | Sets the "tolerance before" value for the CIM, vertical section | 50 |
| DWGSLABVERTSECTIONRCALL | Sets if "Include all reinforcement" should be marked as default in the vertical section | 0 |
| DWGSLABVERTSECTIONRCTOLERANCEAFTER | Sets the "tolerance after" value for the reinforcement, vertical section | 10 |
| DWGSLABVERTSECTIONRCTOLERANCEBEFORE | Sets the "tolerance before" value for the reinforcement, vertical section | 10 |
| DWGTEXTSTRANDGRP | Sets what text should be written next to the section for the strand group | 0 |
Solid slab
| Variable | Short description | Default value |
| ANNOTATIONBYMOULDSIDESOLIDSLAB | Changes the annotation of CIM:s, recesses, lifts, etc due to the cast type of the solid slab. | 0 |
| AUTOCHECKPRODUCIBILITYSOLIDSLAB | Does a producibility check automatically without creating a Unitechnik file on the following commands:
| 0 |
| AUTO_EXPORT_OBJ_SOLID_SLAB | Determine if the obj file should be created/updated with the solid drawing view. | 0 |
| AUTOEXPORTUNITECHNIKSOLIDSLAB | Exports a Unitechnik file automatically on the following commands:
| 0 |
| SOLIDSLABSECTIONSCALE | Controls the slab section scale, if the value is set to 50 then the scale will be 1:50. Default value 1:20 | 1:20 |
| DWGDIMFLOORPLANCUTSLAB | Enables a dimension of the width of the slab to be drawn inside the element when the width of the slab is less than the width specified in its definition. | 0 |
| DWGSHOWSINGLESECTIONNAMESLAB | Enables letters on each section arrow | 0 |
| DWGDIMSLABLIFT | Controls lift measurements of wide slabs | 1 |
Prestressed Solid slab
| Variable | Short description | Default value |
| AUTOCHECKPRODUCIBILITYPRESLAB | Does a producibility check automatically without creating a Unitechnik file on the following commands:
| 0 |
| AUTO_EXPORT_OBJ_PRE_SLAB | Determine if the obj file should be created/updated with the solid drawing view. | 0 |
| AUTOEXPORTUNITECHNIKPRESLAB | Exports a Unitechnik file automatically on the following commands:
| 0 |
| DWGDIMFLOORPLANCUTPRESLAB | Enables a dimension of the width of the slab to be drawn inside the element when the width of the slab is less than the width specified in its definition. | 0 |
| Controls lift measurements of prestressed wide slabs | 1 |
Hollow core
| Variable | Short description | Default value |
| AUTO_EXPORT_OBJ_HOLLOW_CORE | Determine if the obj file should be created/updated with the solid drawing view. | 0 |
| HCSMINIMUMCUTGAP | Controls gap between hollow core elements | 0 |
| DWGTEXTCONNECTIONRECESS | Text that is shown for the connection recess on the edge | R $S $L $W $H |
| DWGTEXTCONNECTIONRECESSWIDTH | Text that is shown for the connection recess | R %%c$D |
| DWGDIMFLOORPLANCUTHCS | Enables a dimension of the width of the slab to be drawn inside the element when the width of the slab is less than the width specified in its definition. | 0 |
| DWGTEXTCORE | Prefix for the core number | C |
| DWGTEXTCOREFILLING | A header for the core filling | CORE FILLING |
| DWGTEXTHCSENDCAPCUTOUT | Text on the dimension line for a cut out in the endcap | R TC |
| DWGTEXTHCSENDCAPRECESS | Text on the dimension line for a recess in the endcap | R T |
| DWGTEXTHCSLIFTANNOTATION | A header for the lift | Core |
| DWGTEXTHCSLIFTCOREANNOTATION | Prefix for the lift number | C |
| DWGTEXTHCSENDCAPHOLE | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
| DWGTEXTHCSENDCAPHOLE1 | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
| DWGTEXTHCSENDCAPHOLEHOLE | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
| DWGTEXTHCSENDCAPHOLEHOLE1 | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
| DWGTEXTHCSENDCAPHOLETOP | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
| DWGTEXTHCSENDCAPHOLETOP1 | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
| DWGTEXTHCSENDCAPNONE | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
| DWGTEXTHCSENDCAPNONE1 | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
| DWGTEXTHCSENDCAPTOP | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
| DWGTEXTHCSENDCAPTOP1 | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
| DWGTEXTHCSENDCAPTOPHOLE | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
| DWGTEXTHCSENDCAPTOPHOLE1 | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
| DWGTEXTHCSENDCAPTOPTOP | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
| DWGTEXTHCSENDCAPTOPTOP1 | Text that can be shown if attributes are added in the specification or the drawing panel | 0 |
| DWGTEXTSECTIONSCALE | Strandpattern scale can be changed with this variable | 1:$SCALE |
| DWGTEXTSTRANDPATTERN | Strandpattern description can be changed with this variable | $NAME |
| SHOWNONCLEANEDCORESINMODEL | Shows the hatch for clean cores on floor plans | 0 |